BM-1600 Time Based
Brake Monitor
Diagnostic Display

Brake Warning
Indicator Yellow light illuminates when the
set point is exceeded. Excellent input for the press
operator and for maintenance.
Drive Failure Red LED illuminates when the pulses from the
encoder disappear while the brake remains
released.
Brake on Yellow light illuminates when power to the
dual solenoid valve drops out.
Ready Green LED illuminates when all systems are
go.
Not Ready Red LED illuminates when the brake monitor
safety relays have dropped out. Example: drive failure,
internal failure, etc.
+/- Pushbuttons The +/- pushbuttons are used to set the time
values in milliseconds for the brake warning and the
brake limit set points.
System Programming Security and
Safety Keyed selector switch
controls:
- Brake Warning Time Set point
- Brake Limit Time Set point
- System Reset
- System Run
Brake Failure
Indicator Red light illuminates when the actual brake
stopping time exceeds the programmed brake limit set
point.
Stop Time Displayed in milliseconds after every stop
in machine cycle and the red LED is
illuminated.
RPM/SPM Displayed during each press cycle when the
red LED is illuminated.
Brake Warning Time Displayed in milliseconds when the red LED
is illuminated.
Brake Limit Time Set point is displayed in milliseconds when
the red LED is illuminated.