BM-1600 Time Based
Brake Monitor
Specifications

Controller
|
Power
|
|
Standard:
|
120
+/- 10% VAC, 50-60hz, 8
Watts
|
|
Optional:
|
240
+/- 10% VAC, 50-60hz, 8
Watts
|
|
Optional:
|
24
+/- 10% VDC, 8 Watts
|
|
Relay
Configuration
|
|
Dual self-checking
force-guided captive contact safety
relays
|
|
Relay Contact
Rating
|
|
8 amps @ 250VAC resistive
for safety relays
4 amps @ 250VAC resistive for alarm
relay
|
|
System
Accuracy
|
|
+/- 1
millisecond
|
|
Set
Points
|
|
Drive
failure:
|
1
to 25 tenths of a
second
|
|
Brake
warning:
|
1
to 999 milliseconds
|
|
Brake
failure:
|
1
to 999 milliseconds
|
|
Display
|
|
Speed:
|
0
to 290 +/- 1 RPM
291 to 999 +/- 4 RPM
|
|
Stop
Time:
|
0 to 999 +/- 1
msecs.
|
|
Indicators
|
|
Brake Fault – Red LED
Brake Warning – Yellow LED
Drive Failure – Red LED
Brake ON – Yellow LED
Ready – Green LED
Not Ready – Red LED
Stop Time Display – Red LED
RPM – Red LED
Brake Warning Setpoint – Red LED
Brake Limit Setpoint – Red
LED
|
|
Inputs
|
|
Encoder:
|
See
Below
|
|
Clutch:
|
120 +/- 10%
VAC
|
|
Output
Circuit
|
|
Two captive contact
self-checking N.O. relays in series.
Isolated (DRY) Normally open contacts
--||--||--
Alarm relay will close when a warning or
failure setpoint is
exceeded.
|
|
Operating
Temperature
|
|
0° to 50°
C
|
|
Enclosure
|
|
Lockable NEMA 12
steel
|
|
Enclosure
Dimensions
|
|
8” (203mm) Height x 7”
(178mm) Width x 4” (127mm)
Depth
|
Encoder (Part #E-160 - CW or CCW Rotation
Capable)
|
Cable
|
|
20’ (6m) is supplied
standard; 100’ (2540mm) maximum
length.
Gauge: 20 AWG – 3 connectors plus drain
Rating: 300 VAC @ 60
C
|
|
Shaft
Loading
|
|
Radial: 35 lbs.
Axial: 40
lbs.
|
|
Operating
Temperature
|
|
0° to 50°
C
|
|
Dimensions
|
|
5.5" (140mm) Height x 3.75"
(95mm) Width x 3-9/16" (90mm)
Depth
|
Print this page
|