Die Protection Sensor Interface
Remote Die Box

The six (6) channel remote die box allows you to quickly change
out the die sensors by using either plug connectors or Banana jacks. Provides +24VDC power to active sensors
and monitors the status (PNP or NPN).
To order the Die Protection Sensor Interface Remote Die Box, order part number
53-450.
Part Number 53-450 includes:
-
Six (6) channel remote die box
-
Individual Channel Indicators
-
Cable - 45' quick disconnect (12 conductor) minimizes wiring installation time
-
Power supply is included to power sensors - 24VDC at 2.5 AMP
Indicator LED's
GREEN = NPN
RED = PNP
Banana Jack:
Passive GND sensors. When used you must jumper Pin 1 to 3 on Lumberg receptacle
(female) (i.e. NPN only)
Installation
Apply 120vac L & N to Brown & RED/White stripe, Earth
GND to RED & Shield wires.
Attach your Die Sensors to the Jacks. Wire the Die#
out Pins to the Die inputs of your control.
Connect the Violet Ground wire to the Ground of your
control so they are common.
If you use the built in 24vdc power supply, you may
also be required to disable other 24vdc sources and use this
one only.
Active PNP or NPN
Sensors
|
Pin
|
Description |
|
1
|
Jumper to Pin 3 if NPN, to Pin 4 if PNP |
|
2
|
Sensor Output (NPN or PNP) |
|
3
|
+24VDC from Die Box power supply |
|
4
|
Ground from Die Box power supply |

|
Enclosure:
|
NEMA 12, 13, IP54 painted steel
(blue)
|
|
Dimensions:
|
8" (203mm) Height
6" (152mm) Wide
3.5" (89mm) Deep
|
45' of 16 Pin Circular Connection
Cable
|
Pin
|
Wire Color
|
Description
|
|
1
|
BRN
|
120VAC L input
|
|
2
|
N/C
|
|
|
3
|
RED
|
Earth Ground
|
|
4
|
ORG
|
+24v out (from power supply)
|
|
5
|
YEL
|
+24v out (from power supply)
|
|
6
|
GRN
|
Die #6 output
|
|
7
|
Shield
|
Case Ground
|
|
8
|
N/C
|
|
|
9
|
BLU
|
Die #5 output
|
|
10
|
VLT
|
Ground
|
|
11
|
GRY
|
Die #2 output
|
|
12
|
WHT
|
Die #1 output
|
|
13
|
BLK
|
Die #3 output
|
|
14
|
BK/WT
|
Die #4 output
|
|
15
|
RD/WT
|
120VAC N input
|
|
16
|
N/C
|
|

Print this page
|