Designed for installation in tight areas, on smaller presses, or by pendent mounting for convenient operator access to the press controls and machine status.

  • Exceeds OSHA 1910.217 & ANSI B11.1-2001
  • Designed to be free standing
  • Utilizes existing motor starters and main power disconnects in a separate enclosure
  • Quick and Easy Installation
  • Control Reliable Design (Triple CPU Redundancy)
  • Incorporates dual logic power supplies
  • Heavy duty resolver supplied standard with self-checking input on every press cycle and 30' of resolver cabling supplied standard
  • Complete system diagnostics and programming in plain English/Spanish/French by a four line by twenty character vacuum fluorescent display
  • Can control up to four sets of operator stations
  • Operates at 24VDC, 110VAC, or 240 VAC/440 VAC
  • Major faults such as E-Stop, motion, brake monitor, and sensor faults are handled by two force-guided relays (Form B safety relays)
  • Modes of operation: off--inch--single--continuous
  • Continuous ARM; top stop, anti-tie down and anti-repeat
  • System start/stop functions
  • SPM Range -1 to 500
  • Password and supervisory controlled keyed selector switch for security of data entry
  • Interrupted stroke provision with indicator
  • Inch mode monitoring
  • Crank angle and speed readout (SPM)
  • Time-based brake monitor
  • Built-in motion detector and drift fault
  • 90° and 270° stop time tester/meter built-in
  • Built-in hour meter for maintenance
  • Built-in variable speed compensation
  • Servo-feed interface built-in
  • Six optically isolated die protection inputs that can be either AC or DC (sourcing or sinking)
  • Six limit switch outputs can be set to cycle (non-timed) two times per crank rotation by setting an open/close crank angle (AC or DC @ 3A)
  • The last three limit switch outputs can be set for timed, non-timed, delay, hold, or cycle two times per crank revolution (AC or DC @ 3A)
  • Six PLS (programmable limit switch) output relays are small, high speed, and high capacity (AC or DC @ 3A)
  • 100 job memory (removable)
  • Stroke, batch, quality, and part counters
  • Batch counter output relay
  • Die protection output relay (opens when there is a fault)
  • Speed output relay (opens when press speed falls out of the max/min parameters)
  • Auxiliary output relay (customer assigned usage)
  • Optional tonnage monitoring
  • Optional Ethernet or DeviceNet communication
  • PC Link to allow offline job creation and storage
  • Safety relay controller built-in
  • Two-year warranty

Dimensions for the SFP