Small Form Package
Overview

Designed for
installation in tight areas, on smaller presses, or by
pendent mounting for convenient operator access to the
press controls and machine status.
- Exceeds OSHA 1910.217 & ANSI
B11.1-2001
- Designed to be
free standing
- Utilizes existing
motor starters and main power disconnects in a
separate enclosure
- Quick and Easy
Installation
- Control Reliable Design (Triple CPU
Redundancy)
- Incorporates dual logic power
supplies
- Heavy duty resolver supplied standard
with self-checking input on every press cycle and 30'
of resolver cabling supplied
standard
- Complete system diagnostics and
programming in plain English/Spanish/French by a four
line by twenty character vacuum fluorescent
display
- Can control up to four sets of operator
stations
- Operates at 24VDC, 110VAC, or 240
VAC/440 VAC
- Major faults such as E-Stop, motion,
brake monitor, and sensor faults are handled by two
force-guided relays (Form B safety
relays)
- Modes of operation:
off--inch--single--continuous
- Continuous ARM; top stop, anti-tie down
and anti-repeat
- System start/stop
functions
- SPM Range -1 to
500
- Password and supervisory controlled
keyed selector switch for security of data
entry
- Interrupted stroke provision with
indicator
- Inch mode
monitoring
- Crank angle and speed readout
(SPM)
- Time-based brake
monitor
- Built-in motion detector and drift
fault
- 90° and 270° stop time tester/meter
built-in
- Built-in hour
meter for maintenance
- Built-in variable speed
compensation
- Servo-feed interface
built-in
- Six optically isolated die protection
inputs that can be either AC or DC (sourcing or
sinking)
- Six limit switch outputs can be set to
cycle (non-timed) two times per crank rotation by
setting an open/close crank angle (AC or DC @
3A)
- The last three limit switch outputs can
be set for timed, non-timed, delay, hold, or cycle
two times per crank revolution (AC or DC @
3A)
- Six PLS (programmable limit switch)
output relays are small, high speed, and high
capacity (AC or DC @
3A)
- 100 job memory
(removable)
- Stroke, batch, quality, and part
counters
- Batch counter output
relay
- Die protection output relay (opens when
there is a fault)
- Speed output relay (opens when press
speed falls out of the max/min
parameters)
- Auxiliary output relay (customer
assigned usage)
- Optional tonnage
monitoring
- Optional Ethernet or DeviceNet
communication
- PC Link to allow offline job creation
and storage
- Safety relay
controller built-in
- Two-year
warranty
Dimensions for the
SFP

Print this page
|
|
|