Brake
Warning Indicator
Yellow light illuminates
when the set point is exceeded. Excellent input for the press
operator and for maintenance.
Drive Failure
Red LED illuminates when
the pulses from the encoder disappear while the brake remains
released.
Brake on
Yellow light illuminates
when power to the dual solenoid valve drops out.
Ready
Green LED illuminates
when all systems are go.
Not Ready
Red LED illuminates when
the brake monitor safety relays have dropped out. Example: drive
failure, internal failure, etc.
+/- Pushbuttons
The +/- pushbuttons are
used to set the time values in milliseconds for the brake warning
and the brake limit set points.
System Programming Security and
Safety
Keyed selector switch
controls:
- Brake Warning Time Set
point
- Brake Limit Time Set
point
- System Reset
- System Run
Brake Failure Indicator
Red light illuminates
when the actual brake stopping time exceeds the programmed brake
limit set point.
Stop Time
Displayed in milliseconds
after every stop in machine cycle and the red LED is illuminated.
RPM/SPM
Displayed during each
press cycle when the red LED is illuminated.
Brake Warning Time
Displayed in milliseconds
when the red LED is illuminated.
Brake Limit Time
Set point is displayed
in milliseconds when the red LED is illuminated.