Controller |
|
Power: |
Standard:
Optional:
Optional: |
120 +/- 10% VAC, 50-60hz, 8 Watts
240 +/- 10% VAC, 50-60hz, 8 Watts
24 +/- 10% VDC, 8 Watts |
|
Relay Configuration: |
Dual self-checking force-guided captive contact safety relays |
|
Relay Contact Rating: |
8 amps @ 250VAC resistive for safety relays
4 amps @ 250VAC resistive for alarm relay |
|
System Accuracy: |
+/- 1 millisecond |
|
Set Points: |
Drive failure:
Brake warning:
Brake failure: |
1 to 25 tenths of a second
1 to 999 milliseconds
1 to 999 milliseconds |
|
Display: |
Speed:
Stop time:
|
0 to 290 +/- 1 RPM
291 to 999 +/- 4 RPM
0 to 999
+/- 1 msecs. |
|
Indicators: |
Brake Fault Red LED
Brake Warning Yellow LED
Drive Failure Red LED
Brake ON Yellow LED
Ready Green LED
Not Ready Red LED
Stop Time Display Red LED
RPM Red LED
Brake Warning Setpoint Red LED
Brake Limit Setpoint Red LED |
|
Inputs: |
Encoder:
Clutch: |
see below
120 +/- 10% VAC |
|
Output Circuit: |
Two captive contact self-checking N.O. relays in series.
Isolated (DRY) Normally open contacts --||--||--
Alarm relay will close when a warning or failure setpoint
is exceeded. |
|
Operating Temperature: |
0° to 50° C |
|
Enclosure: |
Lockable NEMA 12 steel |
|
Enclosure Dimensions: |
8 (203mm) Height x 7 (178mm) Width x 4
(127mm) Depth |