Pressroom Electronics

Pre-Packaged “Control Reliable” Multi-Function Resolver-Based Cyclic PLC Machine Control
Home

Resolver-Based PLC Machine Control

COMMANDER

Exceeds All OSHA & ANSI Regulations
for Machine Controls

 

 

Standard Safety/Automation Features:

• Exceeds OSHA & ANSI Standards
• Quick & Easy Installation
• Control Reliable Design (Triple CPU Redundancy)
• Incorporates dual logic power supplies
• Heavy duty resolver supplied standard with self-checking input on every press cycle and 30' of resolver cabling supplied standard
• Complete system diagnostics and programming in plain English/Spanish by a four line by twenty character vacuum fluorescent display
• Operates at 24VDC, 110VAC
• Major faults such as E-Stop, motion, brake monitor, and sensor faults are handled by two force-guided relays (Form B safety relays)
• Modes of operation: off--inch--single--continuous
• Continuous ARM; top stop, anti-tie down and anti-repeat built-in
• System start/stop functions
• SPM Range -1 to 500 strokes or cycles per minute
• Password and supervisory controlled keyed selector switch for security of data entry
• Interrupted stroke provision with indicator
• Inch mode monitoring aides machine set-up
• Crank angle and speed readout (SPM)
• Time-based brake monitor
• Built-in motion detector and drift fault
• 90° and 270° stop time tester/meter built-in
• Built-in variable speed compensation
• Servo-feed interface built-in
• Six optically isolated die protection inputs that can be either AC or DC (sourcing or sinking)
• Six limit switch outputs can be set to cycle (non-timed) two times per crank rotation by setting an open/close crank angle (AC or DC @ 3A)
• The last three limit switch outputs can be set for timed, non-timed, delay, hold, or cycle two times per crank revolution. (AC or DC @ 3A)
• Six PLS (programmable limit switch) output relays are small, high speed, and high capacity (AC or DC @ 3A)
• 100 job memory (removable)
• Stroke, batch, quality, and part counters
• Batch counter output relay
• Die protection output relay (opens when there is a fault)
• Speed output relay (opens when machine speed falls out of the max/min parameters)
• Auxiliary output relay (customer assigned usage)
• Optional tonnage monitoring
• Add starters, disconnects & additional non-safety controls if necessary
• PC Link to allow offline job creation and storage
• Safety relay controller built-in
• Two-year warranty
• Made in the USA

Installation Manuals
Online Publications
Products & Software
OSHA Regulations
Request Information
Contact Us

 

Pressroom Electronics

Sales & Marketing
(800) 937-4334

Customer Service
(630) 443-9320

 

 

el #PCS-2

PLC Machine Control

View and Print the PDF Commander Brochure

Pressroom Electronics' Product Mix
Presscommander Resolver Based Clutch/Brake Controls for Punch Presses
Rotary Cam Based Clutch/Brake Controls for Punch Presses
Time - Based Brake Monitors • Press Automation Controllers
Punch Press Components • Brake Performance Testers
Machine Guarding Systems