The
Model PCS-2000 Control System is completely pre-wired and ready for installation.
System supplied complete with a well marked terminal strip for easy, safe,
and accurate electrical interface to the various punch press components.
Due to the hybrid design characteristics, a main power disconnect switch
and magnetic motor starter can be supplied in the same control panel.
Customer to specify operator
control location (photo displays operator controls on panel door).
The
proposal/ordering sheet
provides a step-by-step format for designing the control exactly how you
want it.
- NEMA 12 Enclosure
- System Start Guarded Push Button
(Air and Power Interlock)
- System Stop Unguarded Push Button
- System On Indicator Light
- Plain English messages for status and
system self-diagnostics
- Automatic Continuous Set Up Push
Button This prior action push button must be operated to set-up
the press for continuous operation. Once depressed, the operator
has a preset length of time in which to depress both palm buttons
concurrently to initiate operation in the continuous mode.
- Interrupted stroke provision
- Time-Based Brake Monitor
- Ground Fault Detector Oil tight
push to test type wired to continuously monitor press grounding whenever
control power is on.
- Continuous Arm Timer Fused Secondary
Pressure Clamp Terminals
- Hand/Foot Mode Two position keyed
selector for hand or foot mode initiation.
- Transformer To reduce voltage
from 480/240VAC to 120VAC secondary. Consult factory for 208
or 550 volt system.
- Keyed Mode Selector Off-Inch-Single
Continuous Four position keyed lock selector switch for supervised
selection of mode of operation of the press. When in the inch
mode, the operator cannot hold or tie one run button down and use
the other button to inch the press with one hand operation.
Both buttons must be depressed concurrently. Micro-inching and
Automatic External Trip optional.
- Safety relay
controller built-in
|