| Model
PCS-4000 |
||
|
Model PCS-4000 Resolver Based Control System with Components |
Incorporates
all the requirements of OSHA for control reliability and component monitoring.
Also includes component and system diagnostics with indicator lights for
total press monitoring. Complies with section 1910.217 of the Federal
Register and ANSI Standard B11.1-2001.
When foot actuation is used, a method of guarding the point of operation must be provided. Click here for a step-by-step ordering/proposal sheet.
|
|
![]() |
||
| |
Control Package PCS-4000 (features) includes the following: | |
|
Sales
& Marketing Customer
Service |
Dual
Solenoid Valve No. 303 The L-G monitor contains a pressure controlled
spool in an assembly mounted between the pilot and valve body assemblies.
Pressure signals are applied to each end of the monitor spool. If
these signals differ by more than a built-in design limit, they cause
the spool to shift to a latched position. The spool movement causes
the pilots to be exhausted and pilot supply air to be vented to the atmosphere,
thus rendering the valve inoperable. The monitor must be reset by
unlatching the spool before another valve cycle can be initiated. |
Heavy Duty Pressure Switch No. 306 This NEMA 12 oil-tight and dust-tight switch is adjustable from 1 to 115 PSI. |
Filter Regulator Lubricator |
||
Operator Station No. UL-501
|
Industrial
Grade Brushless Resolver Transducer Part No. 40-003 Heavy duty brushless resolver transducer which replaces the current mechanical rotary cam switch. Resolver Cabling 30' Part No. 45-020 |
|

Pressroom
Electronics' Product Mix |