NEMA 12 Enclosure
System Start
Guarded Push Button
(Air and Power Interlock)
System Stop
Unguarded Push Button
System On
Indicator Light
Message Display
Plain English messages for status
and system self-diagnostics
Interrupted Stroke
Provision with Indicator
Explanation
Automatic Continuous
Set Up Push Button
This prior action
push button must be operated to set-up the press for continuous operation.
Once depressed, the operator has a preset length of time in which to
depress both palm buttons concurrently to initiate operation in the
continuous mode.
Brake Monitor--Top
Stop Indicator
Oil tight indicator
light to detect top stop overrun, this light is tied into the rotary
cam to provide an electro-mechanical brake monitoring system. Time-based
brake monitoring optional.
|
Click here for
a step by step format for designing the control exactly how you want it.
Ground Fault
Detector
Oil tight push to test type wired
to continuously monitor press grounding whenever control power is on.
Continuous Arm Timer
Fused Secondary Pressure Clamp Terminals
Hand/Foot Mode
2 Position Keyed Selector for
Hand or Foot Mode Initiation
Transformer
To reduce voltage
from 480/240V to 120 Vac secondary. Consult factory for 208 or 550 volt
system.
Keyed Mode Selector Off-Inch-Single
Continuous
4 position keyed lock selector switch for supervised selection of mode
of operation of the press. When in the inch mode the operator cannot hold
or tie one run button down and use the other button to inch the press
with one hand operation. Both buttons must be depressed concurrently.
Micro-Inching and Automatic External Trip optional.
LED Diagnostics
Punch Press Components and System
Diagnostics with LED Indicator Lights, on printed circuit boards for all
inputs and outputs.