Control Package 1500SS |
||
|
|
Incorporates
all the requirements of OSHA for control reliability and component monitoring.
Also includes component and system diagnostics with indicator lights for
total press monitoring. Complies with section 1910.217 of the Federal
Register and ANSI Standard B11.1-2001. When foot actuation is used, a method of guarding the point of operation must be provided. Refer to OSHA and ANSI requirements. Control Package 1500 SS (features) includes the following: |
|
Sales
& Marketing Customer
Service |
||
Dual
Solenoid Valve No. 303 The L-G monitor contains a pressure controlled
spool in an assembly mounted between the pilot and valve body assemblies.
Pressure signals are applied to each end of the monitor spool. If
these signals differ by more than a built-in design limit, they cause the
spool to shift to a latched position. The spool movement causes the
pilots to be exhausted and pilot supply air to be vented to the atmosphere,
thus rendering the valve inoperable. The monitor must be reset by
unlatching the spool before another valve cycle can be initiated. |
Heavy Duty Pressure Switch No. 306 This NEMA 12 oil-tight and dust-tight switch is adjustable from 1 to 115 PSI. |
|
Filter Regulator Lubricator |
||
Operator Station
No. UL-501 Two UltraTouch modules mounted on a NEMA 12 operator
station run bar with a red
mushroom emergency stop button located
in the center and a yellow mushroom top
stop button located off center. This style assembly is ideal for the
metal stamping/metal fabrication industry. All the modules are mounted
in accordance with OSHA, ANSI, and CSA standards in regards to run button spacing. |
Rotary Cam Switch
with Drive Check No. 310A This NEMA 12 rotary switch provides limit switch
functions required by control systems. Spring loaded mounting absorbs
shock and will stop the press should the drive chain break. Cams are
easily adjusted with tool provided. |
|