- Vacuum Fluorescent Display - four lines/20 characters
(alphanumeric English/Spanish/French)
- All six Limit Switch Outputs can be set to cycle (non-timed)
two times per crank rotation by setting an open/close crank angle.
- The last three outputs can be set
for timed, non-timed, delayed, and hold or cycled two times per
crank revolution.
- Major faults such as E-Stop, motion,
brake, and sensor faults are handled by two force-guided relays
(Form B Safety relays).
- The six outputs are small, high-speed,
high-capacity relays.
- Brake and die sensor inputs are
optically coupled and can be either AC or DC (sourcing or sinking).
- Up to 100 Jobs can be saved using
a nonvolatile memory chip. The memory chip is removable for ease
of transfer. Each Job Number stores a name and/or number up to
7 characters for easy identification.
- Built-in Brake Monitor will issue
a warning when the programmed warning time is exceeded and will
issue a failure signal when programmed stop time is exceeded.
- True Motion Detection system checks
for lack of motion (Motion Fault) and unintended motion (Drift
Fault).
- SPM Indicator (Strokes per Minute).
- Crank angle shown graphically and
in large numbers.
- Speed compensation of user selected
outputs.
- Servo feed interface.
- Stroke, Batch, Quality, and Part
Counters to keep track of operation.
- Password and/or Supervisory Controlled
Selector Switch to prevent altering of parameters, except for
the counters.
- PCLink to allow offline job creation
and storage.
- Built-in 90° and 270° stop time
tester.
- Safety relay
controller built-in
|