The User
Friendly
Small Form Package (SFP) PressCommander™
Designed for installation in tight areas, on smaller presses, or
by pendent mounting for convenient operator access to the press
controls and machine status.
Configure
the PressCommander for your application using
our Proposal/Ordering
Sheet.
|
Standard Safety/Automation
Features:
- Exceeds OSHA 1910.217 & ANSI B11.1-2001
- Designed to be
free standing
- Utilizes existing
motor starters and main power disconnects in a separate enclosure (refer
back to the PressCommander customization control panel layout located
on page A-4 of the printed Pressroom Electronics Catalog, or on the
PressCommander section of this website)
- Quick and Easy
Installation
- Control Reliable Design (Triple CPU Redundancy)
- Incorporates dual logic power supplies
- Heavy duty resolver supplied standard
with self-checking input on every press cycle and 30' of resolver cabling
supplied standard
- Complete system diagnostics and programming
in plain English/Spanish/French by a four line by twenty character vacuum
fluorescent display
- Can control up to four sets of operator
stations
- Operates at 24VDC, 110VAC, or 240 VAC/440
VAC
- Major faults such as E-Stop, motion,
brake monitor, and sensor faults are handled by two force-guided relays
(Form B safety relays)
- Modes of operation: off--inch--single--continuous
- Continuous ARM; top stop, anti-tie down
and anti-repeat
- System start/stop functions
- SPM Range -1 to 500
- Password and supervisory controlled keyed
selector switch for security of data entry
- Interrupted stroke provision with indicator
- Inch mode monitoring
- Crank angle and speed readout (SPM)
- Time-based brake monitor
- Built-in motion detector and drift fault
- 90° and 270° stop time tester/meter
built-in
- Built-in hour
meter for maintenance
- Built-in variable speed compensation
- Servo-feed interface built-in
- Six optically isolated die protection
inputs that can be either AC or DC (sourcing or sinking)
- Six limit switch outputs can be set to
cycle (non-timed) two times per crank rotation by setting an open/close
crank angle (AC
or DC @ 3A)
- The last three limit switch outputs can
be set for timed, non-timed, delay, hold, or cycle two times per crank
revolution (AC
or DC @ 3A)
- Six PLS (programmable limit switch) output
relays are small, high speed, and high capacity (AC
or DC @ 3A)
- 100 job memory (removable)
- Stroke, batch, quality, and part counters
- Batch counter output relay
- Die protection output relay (opens when
there is a fault)
- Speed output relay (opens when press
speed falls out of the max/min parameters)
- Auxiliary output relay (customer assigned
usage)
- Optional tonnage monitoring
- Optional Ethernet
or DeviceNet communication
- PC Link to allow offline job creation
and storage
- Safety relay controller
built-in
- Two-year warranty
Dimensions for the SFP
|